Grade | Item | MFR | Density | Tensile strength | Tensile elongation | Flexural strength (Olsen) |
Vicat softening point |
Features | Applications |
---|---|---|---|---|---|---|---|---|---|
Test Method | ASTM D1238 | ASTM D1505 | ASTM D638 | ASTM D638 | ASTM D747 | ASTM D1525 | |||
Unit | g/10min | kg/m3 | MPa | % | MPa | ℃ | |||
Tele- communications |
UBEC130 | 0.28 | 920 | 20 | 650 | 150 | 92 | Excellent heat-aging resistance Crosslinkable |
General purpose insulation Irradiation crosslinkable insulation |
UBEC150 | 0.23 | 919 | 21 | 650 | 170 | 93 | High speed extrusion |
For fine insulation | |
UBEC180 | 0.25 | 924 | 21 | 650 | 230 | 100 | High speed extrusion Excellent abrasion resistance |
For fine insulation | |
UBEC450 | 1 | 921 | 18 | 650 | 150 | 92 | Good electrical properties |
Coaxial cable | |
UBEC454 | 1 | 920 | 18 | 650 | 150 | 92 | Good electrical properties High speed extrusion |
Coaxial cable | |
UBEC600V6 | 0.12 | 936 | 21 | 650 | 150 | 94 | Weatherability ESCR |
Sheath cable | |
Z657 | 0.3 | 920 | 24 | 700 | - | 94 | Weatherability (natural) |
General purpose insulation | |
Power | UBEC530 | 1.2 | 920 | 18 | 650 | 150 | 91 | General purpose insulation |
For crosslinkable insulation |
UBEC530S | 1.2 | 920 | 18 | 650 | 150 | 91 | Super-clean | For crosslinkable insulation | |
UBEC130 | 0.28 | 920 | 20 | 650 | 150 | 92 | Excellent heat-aging resistance Crosslinkable |
General purpose insulation Irradiation crosslinkable insulation |
|
Flame Retardant | C791B | 0.4 | 1400 | 12 | 600 | - | - | Non-halogen(black) Flexibility |
Eco cable LOI=40 |
* These values are typical properties and not to be considered as specifications.
* Specimens are prepared from compression-molded sheets.